Teck90 Teck 90 Wire Cable in 10 12 14 8 6 4 3 2 1 1/0 2/0 3/0 4/0 200 300 350 400 500 600 750 mcm awg size
Application: Teck 90 Armored wire cable wire cables wiring cabling is for use in power, control and lighting circuits at industrial and chemical plants, pulp and paper mills, steel mills, mines, power generating facilities, food processing plants and commercial centers. Teck 90 is suitable for installation in wet or dry locations in troughs, trays and in direct burial applications
8AWG – 750MCM Teck 90 wire cable 1000V 90°C
Part Number |
Conductor Size AWG |
No. of Conductors |
Ground Wire AWG |
Insulation Thickness (inches) |
Inner Jacket Thickness (inches) |
Approximate Diameter |
Approx. Weight lbs./1000 ft. |
||
8/3-TECK90 |
8 |
3 |
10 |
0.045 |
0.060 |
0.720 |
0.920 |
1.030 |
486 |
6/3-TECK90 |
6 |
3 |
8 |
0.060 |
0.060 |
0.890 |
1.110 |
1.230 |
741 |
4/3-TECK90 |
4 |
3 |
8 |
0.060 |
0.080 |
0.920 |
1.140 |
1.260 |
944 |
3/3-TECK90 |
3 |
3 |
6 |
0.060 |
0.080 |
1.110 |
1.330 |
1.320 |
1161 |
2/3-TECK90 |
2 |
3 |
6 |
0.060 |
0.080 |
1.050 |
1.270 |
1.380 |
1272 |
1/3-TECK90 |
1 |
3 |
6 |
0.080 |
0.080 |
1.200 |
1.420 |
1.540 |
1556 |
1/0-3-TECK90 |
1/0 |
3 |
6 |
0.080 |
0.080 |
1.280 |
1.500 |
1.620 |
1809 |
2/0-3-TECK90 |
2/0 |
3 |
6 |
0.080 |
0.080 |
1.370 |
1.600 |
1.730 |
2151 |
3/0-3-TECK90 |
3/0 |
3 |
4 |
0.080 |
0.080 |
1.470 |
1.700 |
1.830 |
2590 |
4/0-3TECK90 |
4/0 |
3 |
4 |
0.080 |
0.080 |
1.590 |
1.840 |
1.980 |
3205 |
250/3-TECK90 |
250 |
3 |
4 |
0.090 |
0.110 |
1.790 |
2.040 |
2.180 |
3825 |
300/3-TECK90 |
300 |
3 |
4 |
0.090 |
0.110 |
1.900 |
2.150 |
2.290 |
4378 |
350/3-TECK90 |
350 |
3 |
3 |
0.090 |
0.110 |
2.000 |
2.250 |
2.390 |
4965 |
400/3-TECK90 |
400 |
3 |
3 |
0.090 |
0.110 |
2.100 |
2.350 |
2.520 |
5586 |
500/3-TECK90 |
500 |
3 |
2 |
0.090 |
0.110 |
2.260 |
2.510 |
2.690 |
6701 |
600/3-TECK90 |
600 |
3 |
2 |
0.090 |
0.110 |
2.440 |
2.690 |
2.860 |
7795 |
750/3-TECK90- |
750 |
3 |
2 |
0.090 |
0.110 |
2.640 |
2.890 |
3.070 |
9391 |
All values are nominal and subject to correction. All data subject to change without notice
Application: Teck 90 is for use in power, control and lighting circuits at industrial and chemical plants, pulp and paper mills, steel mills, mines, power generating facilities, food processing plants and commercial centers. Teck 90 is suitable for installation in wet or dry locations in troughs, trays and in direct burial applications. Teck 90 is for applications up to 1000 volts and temperatures from -40°C to +90°C.
Conductors: Teck 90 has class B stranded soft drawn bare copper conductors, per ASTM.
Insulation: Teck 90 has cross-linked polyethylene XLP insulation. Ground: Teck 90 has a bare stranded soft drawn grounding conductor. Inner Jacket: Teck 90 has a black polyvinyl chloride PVC inner jacket.
Armor: Teck 90 has an interlocked aluminum tape armor.
Outer Jacket: Teck 90 has a black polyvinyl chloride PVC outer jacket, which is water, chemical, sunlight and abrasion resistant.
Standards: CSA C22.2, No. 131 CSA C22.2, No. 174
FT – 4 flame test
10ga Teck 90 Teck90 Wire Cable 600V 90°C
Part Number |
Conductor Size AWG |
No. of Conductors |
Ground Wire AWG |
Insulation Thickness (inches) |
Inner Jacket Thickness (inches) |
Approximate Diameter |
Approx. Weight lbs./1000 ft. |
||
10/2-TECK90 |
10 |
2 |
12 |
0.030 |
0.045 |
0.470 |
0.670 |
0.780 |
271 |
10/3-TECK90 |
10 |
3 |
12 |
0.030 |
0.045 |
0.560 |
0.760 |
0.870 |
338 |
10/4-TECK90 |
10 |
4 |
12 |
0.030 |
0.045 |
0.600 |
0.800 |
0.910 |
388 |
10-/5-TECK90 |
10 |
5 |
12 |
0.030 |
0.060 |
0.630 |
0.830 |
0.940 |
453 |
10/6-TECK9 |
10 |
6 |
12 |
0.030 |
0.060 |
0.680 |
0.880 |
1.000 |
511 |
10/7-TECK9 |
10 |
7 |
12 |
0.030 |
0.060 |
0.720 |
0.920 |
1.030 |
562 |
10/8-TECK90 |
10 |
8 |
12 |
0.030 |
0.060 |
0.780 |
0.980 |
1.090 |
620 |
10/9-TECK90 |
10 |
9 |
12 |
0.030 |
0.060 |
0.800 |
1.020 |
1.140 |
707 |
10/10-TECK90 |
10 |
10 |
12 |
0.030 |
0.060 |
0.860 |
1.080 |
1.190 |
767 |
10/12-TECK90 |
10 |
12 |
12 |
0.030 |
0.080 |
0.970 |
1.190 |
1.310 |
917 |
10/15-TECK90 |
10 |
15 |
12 |
0.030 |
0.080 |
1.010 |
1.230 |
1.350 |
1050 |
10/20-TECK90 |
10 |
20 |
12 |
0.030 |
0.080 |
1.150 |
1.370 |
1.490 |
1302 |
10/25-TECK90 |
10 |
25 |
12 |
0.030 |
0.080 |
1.290 |
1.510 |
1.630 |
1552 |
10/30-TECK90 |
10 |
30 |
12 |
0.030 |
0.080 |
1.370 |
1.590 |
1.730 |
1813 |
10/40-TECK90 |
10 |
40 |
12 |
0.030 |
0.080 |
1.540 |
1.760 |
1.900 |
2271 |
10/50-TECK90 |
10 |
50 |
12 |
0.030 |
0.080 |
1.690 |
1.940 |
2.080 |
2864 |
All values are nominal and subject to correction. All data subject to change without notice.
Application: Teck 90 is for use in power, control and lighting circuits at industrial and chemical plants, pulp and paper mills, steel mills, mines, power generating facilities, food processing plants and commercial centers. Teck 90 is suitable for installation in wet or dry locations in troughs, trays and in direct burial applications. Teck 90 is for applications up to 600 volts and temperatures from -40°C to +90°C.
Conductors: Teck 90 has class B stranded soft drawn bare copper conductors, per ASTM.
Insulation: Teck 90 has cross-linked polyethylene XLP insulation. Ground: Teck 90 has a bare stranded soft drawn grounding conductor. Inner Jacket: Teck 90 has a black polyvinyl chloride PVC inner jacket.
Armor: Teck 90 has an interlocked aluminum tape armor.
Outer Jacket: Teck 90 has a black polyvinyl chloride PVC outer jacket, which is water, chemical, sunlight and abrasion resistant.
Standards: CSA C22.2, No. 131 CSA C22.2, No. 174
FT – 4 flame test
12ga 12awg 12 awg Teck 90 Wire Cable 600V 90°C
Part Number |
Conductor Size AWG |
No. of Conductors |
Ground Wire AWG |
Insulation Thickness (inches) |
Inner Jacket Thickness (inches) |
Approximate Diameter |
Approx. Weight lbs./1000 ft. |
||
12/2-TECK90 |
12 |
2 |
14 |
0.030 |
0.045 |
0.420 |
0.620 |
0.730 |
223 |
12/3-TECK90 |
12 |
3 |
14 |
0.030 |
0.045 |
0.440 |
0.640 |
0.750 |
256 |
12/4-TECK90 |
12 |
4 |
14 |
0.030 |
0.045 |
0.530 |
0.736 |
0.840 |
308 |
12/5-TECK90 |
12 |
5 |
14 |
0.030 |
0.045 |
0.530 |
0.730 |
0.850 |
338 |
12/6-TECK90 |
12 |
6 |
14 |
0.030 |
0.060 |
0.610 |
0.810 |
0.930 |
401 |
12/7-TECK90 |
12 |
7 |
14 |
0.030 |
0.060 |
0.640 |
0.840 |
0.960 |
437 |
12/8-TECK90 |
12 |
8 |
14 |
0.030 |
0.060 |
0.690 |
0.890 |
1.000 |
479 |
12/9-TECK90 |
12 |
9 |
14 |
0.030 |
0.060 |
0.710 |
0.910 |
1.020 |
512 |
12/10-TECK90 |
12 |
10 |
14 |
0.030 |
0.060 |
0.760 |
0.960 |
1.080 |
555 |
12/12-TECK90 |
12 |
12 |
14 |
0.030 |
0.060 |
0.820 |
1.040 |
1.160 |
669 |
12/15-TECK90 |
12 |
15 |
14 |
0.030 |
0.060 |
0.860 |
1.080 |
1.200 |
761 |
12/20-TECK90 |
12 |
20 |
14 |
0.030 |
0.080 |
1.020 |
1.240 |
1.360 |
981 |
12/25-TECK90 |
12 |
25 |
14 |
0.030 |
0.080 |
1.140 |
1.360 |
1.480 |
1160 |
12/30-TECK90 |
12 |
30 |
14 |
0.030 |
0.080 |
1.220 |
1.440 |
1.560 |
1320 |
12/50TECK90 |
12 |
50 |
14 |
0.030 |
0.080 |
1.490 |
1.710 |
1.850 |
1983 |
12/100TECK90 |
12 |
100 |
14 |
0.030 |
0.110 |
2.090 |
2.340 |
2.480 |
3815 |
All values are nominal and subject to correction. All data subject to change without notice.
Application: Teck 90 is for use in power, control and lighting circuits at industrial and chemical plants, pulp and paper mills, steel mills, mines, power generating facilities, food processing plants and commercial centers. Teck 90 is suitable for installation in wet or dry locations in troughs, trays and in direct burial applications. Teck 90 is for applications up to 600 volts and temperatures from -40°C to +90°C.
Conductors: Teck 90 has class B stranded soft drawn bare copper conductors, per ASTM.
Insulation: Teck 90 has cross-linked polyethylene XLP insulation. Ground: Teck 90 has a bare stranded soft drawn grounding conductor. Inner Jacket: Teck 90 has a black polyvinyl chloride PVC inner jacket.
Armor: Teck 90 has an interlocked aluminum tape armor.
Outer Jacket: Teck 90 has a black polyvinyl chloride PVC outer jacket, which is water, chemical, sunlight and abrasion resistant.
Standards: CSA C22.2, No. 131 CSA C22.2, No. 174
FT – 4 flame test
14ga 14 awg 14awg Teck 90 wire cable 600V 90°C
Part Number |
Conductor Size AWG |
No. of Conductors |
Ground Wire AWG |
Insulation Thickness (inches) |
Inner Jacket Thickness (inches) |
Approximate Diameter |
Approx. Weight lbs./1000 ft. |
||
14/2-TECK90 |
14 |
2 |
14 |
0.030 |
0.045 |
0.380 |
0.580 |
0.690 |
194 |
14/3-TECK90 |
14 |
3 |
14 |
0.030 |
0.045 |
0.450 |
0.650 |
0.760 |
233 |
14/4-TECK90 |
14 |
4 |
14 |
0.030 |
0.045 |
0.480 |
0.680 |
0.790 |
259 |
14/5-TECK90 |
14 |
5 |
14 |
0.030 |
0.045 |
0.480 |
0.680 |
0.790 |
278 |
14/6-TECK90 |
14 |
6 |
14 |
0.030 |
0.045 |
0.520 |
0.720 |
0.830 |
309 |
14/7-TECK90 |
14 |
7 |
14 |
0.030 |
0.045 |
0.550 |
0.750 |
0.860 |
336 |
14/8-TECK90 |
14 |
8 |
14 |
0.030 |
0.060 |
0.620 |
0.820 |
0.940 |
389 |
14/9-TECK90 |
14 |
9 |
14 |
0.030 |
0.060 |
0.640 |
0.840 |
0.950 |
411 |
14/10-TECK90 |
14 |
10 |
14 |
0.030 |
0.060 |
0.680 |
0.880 |
1.000 |
443 |
14/11-TECK90 |
14 |
11 |
14 |
0.030 |
0.060 |
0.720 |
0.920 |
1.030 |
473 |
14/12-TECK90 |
14 |
12 |
14 |
0.030 |
0.060 |
0.740 |
0.940 |
1.050 |
497 |
14/15-TECK90 |
14 |
15 |
14 |
0.030 |
0.060 |
0.770 |
0.970 |
1.080 |
559 |
14/20-TECK90 |
14 |
20 |
14 |
0.030 |
0.060 |
0.880 |
1.100 |
1.210 |
726 |
14/25-TECK90 |
14 |
25 |
14 |
0.030 |
0.080 |
1.020 |
1.240 |
1.360 |
899 |
14/3-TECK90 |
14 |
30 |
14 |
0.030 |
0.080 |
1.090 |
1.310 |
1.430 |
1013 |
14/40-TECK90 |
14 |
40 |
14 |
0.030 |
0.080 |
1.210 |
1.430 |
1.550 |
1237 |
14/50-TECK9 |
14 |
50 |
14 |
0.030 |
0.080 |
1.330 |
1.550 |
1.670 |
1459 |
All values are nominal and subject to correction. All data subject to change without notice.
Application: Teck 90 is for use in power, control and lighting circuits at industrial and chemical plants, pulp and paper mills, steel mills, mines, power generating facilities, food processing plants and commercial centers. Teck 90 is suitable for installation in wet or dry locations in troughs, trays and in direct burial applications. Teck 90 is for applications up to 600 volts and temperatures from -40°C to +90°C.
Conductors: Teck 90 has class B stranded soft drawn bare copper conductors, per ASTM.
Insulation: Teck 90 has cross-linked polyethylene XLP insulation. Ground: Teck 90 has a bare stranded soft drawn grounding conductor. Inner Jacket: Teck 90 has a black polyvinyl chloride PVC inner jacket.
Armor: Teck 90 has an interlocked aluminum tape armor.
Outer Jacket: Teck 90 has a black polyvinyl chloride PVC outer jacket, which is water, chemical, sunlight and abrasion resistant.
Standards: CSA C22.2, No. 131 CSA C22.2, No. 174
FT – 4 flame test
Teck90 Teck 90 Wire Cable
Visit us at our other webs:
midsouthcable.com midsouthelectronics.com midsouthglobal.net
webnetcable.com webelectrical.net ruggednetworks.net inetparts.com midsouthlighting.com
Inventory is subject to prior sale. Product design, specifications & construction are subject to change without notice. Pictures are for general representational purposes and may not represent actual product. Not Responsible for errors in print, verify all data with us or manufacturer. Terms & Conditions of sale apply, for a copy contact us. Listed values are approximate and for general estimation purposes only.
Products may be discontinued without notice. Other disclaimers may apply. **Minimum order quantities apply. All data is subject to change.
inetparts.com Electrical Electronic Industrial Parts and Products Index
AAAC All Aluminum 6201 Alloy Conductor Wire Cable
AAC All Aluminum Conductor Wire Cable
ACSR Aluminium Conductor Steel Reinforced Cable
CONDUIT ELBOWS
Explosion Proof Unit Heaters – GUX
Fiber Optic Cable
Figure 8 Telephone Cable
Fire Alarm Cable Armored MC FPLP
Fire Alarm Cable Plenum & Riser
Innerduct
LED Lighting
MC Feeder Cable Large Size with Aluminum Armor
MC Wire Cable Parking Deck Lot PVC Jacketed
Mining Portable Power Cable Cord
Photovoltaic PV Cable Aluminum 2kv
SHD-GC Portable Power Cord 2kv 5kv 8kv 15kv 25kv
Stainless Steel Conduit Systems 304 and 316
Temporary Power Equipment
VFD Cable
inetparts.com Electrical Electronic Industrial Parts and Products Index
Teck90 Teck 90 Wire Cable
SIGNAMAX NETWORK CONNECTIVITY PRODUCTS
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|